Prime Power SKU KCS-PRIME-POWER-2-5

Prime Power 2.5 mm² Electrical Cable

KSh 8,500 per roll
In stock — pick up today in Nairobi CBD

Prime Power 2.5 mm² cable is electrical wiring cable with a 2.5 square millimetre conductor size, a common size for socket-outlet circuits and for powering equipment such as CCTV recorders, power supplies and electric fence energisers. It is used by electricians and installers across Kenya.

  • 2.5 mm² conductor size
  • Common size for socket-outlet circuits
  • Powers CCTV, fence and gate equipment
  • For installation by a qualified electrician
  • Pickup from 3 Nairobi branches
  • Nairobi delivery from KSh 200 (KSh 50/km)
  • Countrywide courier in 1–3 working days
  • Pay by M-Pesa, cash or bank transfer

Overview

Prime Power 2.5mm electrical cable has conductors with a cross-section of 2.5 square millimetres (mm²). This size is widely used in Kenyan buildings for socket-outlet circuits, and installers use it to bring mains power to equipment such as CCTV recorders and power supplies, electric fence energisers, gate motors and access control panels.

What 2.5 mm² means

The number refers to the cross-sectional area of each copper conductor, not the outside diameter of the cable. A larger area carries more current with less heating and voltage drop. 2.5 mm² is heavier than the 1.5 mm² cable usually used for lighting circuits and lighter than the 4 mm² and 6 mm² cables used for cookers, showers and sub-mains. The right size for any circuit depends on the load, the length of the run, the installation method and the protective device, so the choice should be made by a qualified electrician.

Where to use it

  • Socket-outlet circuits in homes, shops and offices
  • Power feeds to CCTV recorders, camera power supplies and network cabinets
  • Supplies to electric fence energisers, gate motors and access control panels
  • Spurs to equipment in guard houses and outbuildings

Installation and safety

Mains wiring in Kenya should be done by a licensed electrician, following the wiring regulations, with the right circuit breaker for the cable and load. Run the cable in conduit or trunking, keep it separate from data and CCTV cables, and avoid crushing or sharp bends. Use the correct colours for live, neutral and earth, tighten terminals firmly, and test the circuit before switching on. For runs outdoors or underground, use cable rated for that environment, such as armoured cable, in suitable conduit.

What you need with it

  • Conduit or trunking, with bends and couplers
  • Junction boxes, sockets or isolators as required
  • A circuit breaker of the correct rating at the distribution board

Ask our team at the Kefa CCTV Shop on Moi Avenue, Nairobi for the exact specification of the cable in stock, including core type, colour and roll length. Collect in Nairobi CBD or order for delivery across Kenya.

Frequently asked questions

What is 2.5 mm² cable used for?

In most buildings, 2.5 mm² cable is the standard size for socket-outlet circuits. Installers also use it to bring mains power to equipment such as CCTV recorders, camera power supplies, electric fence energisers and gate motors. Lighting circuits normally use the smaller 1.5 mm², while cookers and showers need larger sizes.

Is 2.5 mm² the same as the cable diameter?

No. 2.5 mm² is the cross-sectional area of each conductor, not the width of the cable. The outside diameter is larger because of the insulation and sheath. When buying conduit or glands, measure the actual cable or ask our team, rather than going by the 2.5 figure.

Can I use it outdoors or underground?

Ordinary wiring cable is meant for indoor installation in conduit or trunking. For runs across a compound, to a gate or underground, use cable designed for that environment, such as armoured cable, laid at the right depth in suitable duct. A licensed electrician can advise on the right cable for the route.

Do I need an electrician to install it?

Yes. Mains wiring should be installed by a licensed electrician who can size the cable and circuit breaker for the load and length, follow the wiring regulations, and test the circuit before it is switched on. Poor connections and undersized cable are a common cause of overheating and electrical fires.

KSh 8,500 In stock